Model No.:NM200A
ECG |
LeadMode 5Leads ( R, L, F, N, C or RA, LA, LL,RL,V) |
Leadselection I,II, III, avR, avL, avF, V, |
Waveform 3ch |
Leadmode 3Leads ( R, L, F or RA, LA, LL) |
Leadselection I,II, III, |
Waveform 1ch |
Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto |
HRand Alarm |
Range: Adult 15 ~ 300 bpm Neo/Ped 15~ 350 bpm |
Accuracy ± 1% or ± 1bpm,which great |
Resolution 1 bpm |
Sensitivity > 200 (uV P-P) |
DifferentialInput Impedance > 5 MΩ |
CMRR:Monitor > 105 dB,Operation > 105 dB,Diagnosis > 85 dB |
Electrodeoffset potential ±300mV |
LeakageCurrent <10 uA |
BaselineRecovery <3 S After Defi. |
ECGSignal Range ±8 m V ( Vp-p ) |
Bandwidth: Surgery 1~ 15 Hz,Monitor 0.5 ~ 35 Hz,Diagnostic 0.05 ~ 100 Hz |
CalibrationSignal 1(mV p-p), Accuracy :±5% |
STSegment Monitoring Range |
Measureand Alarm -2.0 ~ +2.0 mV |
ARRDetecting |
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T,VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Alarm Available |
Review Available |
|
|
RESPARATION |
Method Impedancebetween R-F(RA-LL) |
Differential Input Impedance >2.5 MΩ |
MeasuringImpedance Range: 0.3~5.0Ω |
Baseline Impedance Range: 0 – 2.5 KΩ |
Bandwidth 0.3 ~ 2.5Hz |
Resp.Rate |
Measuring and Alarm Range:Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm |
Resolution 1rpm |
Accuracy ±2 rpm |
ApeanAlarm 10~ 40 S |
|
NIBP |
|
Mode Manual, Auto,STAT |
Measuring Interval in AUTO Mode |
1,2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) |
Measuring Period in STAT Mode 5 Min |
Pulse Rate Range 40 ~ 240 bpm |
AlarmType SYS,DIA, MEAN |
Measuringand alarm range: |
Adult Mode:SYS 40 ~ 270 mmHg,DIA 10 ~ 215 mmHg,MEAN 20 ~ 235 mmHg |
Pediatric Mode:SYS 40 ~ 200 mmHg,DIA 10 ~ 150 mmHg,MEAN 20 ~ 165 mmHg |
Neonatal Mode:SYS 40 ~ 135 mmHg,DIA 10 ~ 100 mmHg,MEAN 20 ~ 110 mmHg |
Resolution :Pressure 1mmHg |
Accuracy: Pressure |
MaximumMean error ±5mmHg |
MaximumStandard deviation ±8mmHg |
Overpressure Protection |
Adult Mode 297±3 mmHg |
PediatricMode 240±3 mmHg |
Neonatal Mode 147±3 mmHg |
SpO2 |
Alarm Range 0 ~ 100 % |
Resolution 1 % |
Accuracy 70% ~ 100% ±2 % ,0% ~ 69% unspecified |
Actualization interval about 1 Sec. |
Alarm Delay 10 Sec. |
Pulse Rate |
Measuringand Alarm Range 0~254bpm |
Resolution 1bpm |
Accuracy ±2bpm |
Channel 1 |
Measuringand Alarm Range 0 ~ 50 °C |
Resolution 0.1°C |
Accuracy ±0.1°C |
Actualizationinterval about 1 Sec. |
Average Time Constant <10 Sec. |
Hostunit dimension: 175*210mm, Depth 800mm; Net weight 1.3kg,
Packingdimension: 130*380*270mm ; Gross weight 2.6kg
6Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP,PR/HR;
Optional:Mainstream or Sidestream ETCO2 ; Touch screen;
Lightweight, Compact and portable, Fan-less design , Noise free.
Uniquevector display technology ; 8"high resolution color TFT LCD display; Supportbig font display;
7-leadsECG waveforms display in full screen ; Alarm events of all parameters recall
Water-proofdesign; Strong enough against falling down from up to 1 meter high
15kinds analysis of arrhythmia and drug concentrations
5.5hours working capacity of built-in rechargeable battery; Charging timeonly needs 2.5 hours.
NIBPdouble (hardware and software) over-pressure prevention technology for patientsafety from over-inflation; NIBP temperature drifts automatic processing technology(Automatically adjust sensor benchmark) for precise measurement againsttemperature influence
Adopt high withstand voltagecapacitance in ECG terminal; Anti-defibillator, myoelectricity andhigh-frequency electrosurgical equipment
AdvancedSpO2 digital measurement technology ;Lowperfusion up to 0.1%
Suitable for adult,pediatric , neonatal patient